MPR 2000, MPC 2000 Digital Motor Protection Relay

mpr2000MIThe MPR 2000 monitors three phase & ground currents, voltages, and temperature inputs to provide one of the most comprehensive motor protectionpackages available. Wth up to 10 temperature sensors, the MPR 2000 monitors as many as 39 programmable protective functions. It is ideal for high voltage motors, large low voltage motors, and applications where full protection and advanced warning is crucial, such as in the process and chemical industries.

MPC 2000 Digital Motor Protection and Control Relay

Similar to the MPR 2000 except that it also incorporates advanced

control capabilities for all types of starting methods, including soft

starters and variable frequency drives.

The MPC 2000 has been specifically designed for integration into

motor management systems in chemical, petrochemical and other

process systems.

 

mpc2000Motor Protection And Control

  1. Max start time
  2. Too many starts
  3. Undercurrent pre-alarm
  4. Undercurrent trip
  5. Load increase
  6. Stall protection
  7. Short circuit
  8. Overload
  9. Earth Fault pre-alarm
  10. Earth Fault trip
  11. Unbalance current alarm
  12. Unbalance current trip
  13. Thermal pre-alarm
  14. Thermal trip
  15. Under-voltage
  16. Over-voltage pre-alarm
  17. Over-voltage trip
  18. Phase loss
  19. Phase sequence
  20. Temp. 1 Pre-alarm and trip (separate setting is available for temp sensor trip)
  21. Temp. 2 Pre-alarm and trip
  22. Temp. 3 Pre-alarm and trip
  23. Temp. 4 Pre-alarm and trip
  24. Temp. 5 Pre-alarm and trip
  25. Temp. 6 Pre-alarm and trip
  26. Temp. 7 Pre-alarm and trip
  27. Temp. 8 Pre-alarm and trip
  28. Temp. 9 Pre-alarm and trip
  29. Temp. 10 Pre-alarm and trip

Each protection can be designated as:

  • Trip (or Trip Fail-safe)
  • Alarm Fail-safe
  • Auto Reset
  • Panel Reset
  • Comm. Reset

Discrete Logic Inputs (MPC 2000 Only):

  • Local Start A/B
  • Local/Remote
  • PLC Reset
  • Speed Switch
  • Isolator
  • External Faults 1,2,3
  • Contactor A/B Aux Relay * Local Stop
  • PLC/Serial Port
  • PLC Control
  • Plant Interlock
  • Contactor A/B Status

Communications

Full access through : RS485 with Modbus protocol

True R.M.S. Measurements

  • Voltage, Current, and Resistance at sampling rate of 0.5msec
  • Available with 10 RTDs or 3 Thermistors and 2 RTD's

Outputs - 4 Relays

  • Programmable for Overload, KWHR (energy) Pulse Initiator, or Slave for Alarm
  • Earth Fault
  • Alarm (Fail Safe)
  • Trip (Fail Safe)

Displays - LCD

Measured data :

Voltage - phase to phase

Voltage - phase to neutral

Current each phase

Earth fault current

Resistance each RTD/Thermistor

Power

Power Factor

Calculated data :
Motor current in % of FLC

Thermal capacity

Time to trip

Time to start (after fault)

Unbalanced current

Statistical data :
Total run time

Total number of starts

Total number of trips

Last start time period

Last start current peak

Energy

Fault data :
Last trip

Last alarm

Trip current each phase

Trip earth fault current

Trip voltage (each phase)

Displays - LED's (MPR)

  • On
  • Stopped
  • Starting
  • Running
  • O/L Trip
  • E/F Trip
  • Alarm
  • Trip
  • Internal Failure

 

Displays - LED's (MPC)

  • On
  • Stopped
  • Starting
  • Running
  • Contactor A
  • Contactor B
  • Alarm
  • Trip
  • Internal Failure

 

Typical Applications

  • High voltage and large low voltage motors
  • Motors in the Process Industry
  • Critical motors requiring special protection and/or supervision