RVS-DN line of Low Voltage Soft-Starters
RVS-DN
Which soft starter is considered as the most reliable soft starter in todays' Industrial and Marine markets ?
The RVS-DN is a severe duty, Full Featured, Motor Protection enhanced, Microprocessor-Based, for Motors 4-3500A, 4-3000KW, 208-690V.
For 1000V and 1200V click << RVS-DN for 1000V and 1200V
For 2300V to 15000V click << HRVS-DN Medium Voltage Soft Starter >>.0
View these soft starters in demanding environmental conditions check out our Naval, Marine, Industial, Oil and Gas examples of Solcon soft-starters in a variety of applications
Advantages at a Glance
- Eliminates high inrush current and damaging mechanical shock
- Third generation microprocessor circuitry
- Heavy duty design: 50°C ambient temperature
- Soft, stepless acceleration & deceleration
- Power factor capacitors can be connected directly to the upstream contactor
- Unique starting & stopping characteristics (special characteristics for Ex motors)
- Unique features such as: Pump Control Program, Dual Adjustment, Slow Speed with Electronic Reversing, Energy Save, etc.
- Torque and current starting & stopping characteristics
- Sophisticated motor protection package with Enhanced features
- User friendly, easy installation and operation
- RS485 Communication with MODBUS, PROFIBUS or MODBUS/TCP protocols (others available on request)
- Wide 45-65Hz Auto-tracking frequency range combining special software with unique hardware arrangement allowing starting and stopping while the frequency variates (designed for Marine, Offshore and Generators operating under continuous frequency variation
- Possibility to operate without bypass contactor at 50°C up to 820A
RVS-DN Protection Features
- Start & start inhibit with time delays
- Long start time (Stall protection)
- Electronic shear-pin (Jam) with adjustable curves and delay
- Electronic overload with selectable curves
- Under current with programmable auto reset
- Phase loss
- Phase sequence and Under/Over frequency
- Under/Over voltage with programmable auto reset
- Load loss (indentifying broken drive belt, lack of water in a well, etc.)
- External fault
- Shorted SCR
- Starter over temperature protection
- Motor insulation test (option)
- Motor thermistor (option)
- Analogue Ouput (option)
- When using "Preparation for Bypass" all protective functions remain active
RVS-DN Control
- All inputs & outputs are isolated
- Three C/O output relays
- Thermistor input
- Analogue output
- Communication RS 485 with MODBUS RTU or MODBUS Plus protocols
- User friendly keypad interface allowing precise settings
- Bright LEDs for immediate visual interface
- Interactive and informative 4 language LCD for easy trouble shooting
- Statistical data
- Motor insulation protection
- Hardware and software integration to allow starting from diesel-generator
RVS-DN Construction
- Heavy duty fully rated design (ambient 50°C)
- Compact, light weight
- Cost efficient plug-in control module, identical for sizes B-G
- Preparation for bypass contactor (option), maintaining protection after the bypass contactor is closed
RVS-DN with Motor Protection Features Typical Applications
- Pumps (Water utilities, Industry)
- Compressors
- Conveyors & monorails
- Mixers & Agitators
- Fans & Centrifuges
- Hydraulic pumps
- Starting from weak Mains supply
- Marine (Thrusters, pumps, fans, refrigeration, compressors, etc..)
RVS-DN-AG for two phase motors with Motor Protection Features Typical Applications
Special applications - please contact us

RVS-DN Soft Starter |
||||||||||||
| Starter Type | Motor KW | Motor HP | Starter Size | Dimensions (mm) & Weight | ||||||||
| V~ +10% : -15% | V~ +10% : -15% | |||||||||||
| 230V | 380-440V | 500V | 690V | 230V | 460V | 575V | A-G | W | H | D | Kg | |
| RVS-DN 8 | 2.2 | 4 | 5.5 | 7.5 | 3 | 5 | 7.5 | A | 153 | 310 | 170 | 5 |
| RVS-DN 17 | 4 | 7.5 | 11 | 15 | 5 | 10 | 15 | 153 | 310 | 170 | 5 | |
| RVS-DN 31 | 7.5 | 15 | 16.5 | 22 | 10 | 20 | 30 | 153 | 310 | 217 | 7 | |
| RVS-DN 44 | 11 | 22 | 30 | 37 | 15 | 30 | 40 | 153 | 310 | 217 | 8 | |
| RVS-DN 58 | 15 | 30 | 37 | 45 | 20 | 40 | 50 | 153 | 310 | 217 | 8 | |
| RVS-DN 72 | 18.5 | 37 | 45 | 55 | 25 | 50 | 60 | 153 | 310 | 217 | 8 | |
| RVS-DN 85 | 22 | 45 | 55 | 65 | 30 | 60 | 75 | B | 274 | 370 | 279 | 15 |
| RVS-DN 105 | 30 | 55 | 75 | 90 | 40 | 75 | 100 | 274 | 370 | 279 | 15 | |
| RVS-DN 145 | 37 | 75 | 90 | 132 | 50 | 100 | 125 | 274 | 370 | 279 | 15 | |
| RVS-DN 170 | 45 | 90 | 110 | 160 | 60 | 125 | 150 | 274 | 370 | 279 | 15 | |
| RVS-DN 210 | 55 | 110 | 132 | 185 | 75 | 150 | 200 | C | 590 | 500 | 275 | 45 |
| RVS-DN 310 | 90 | 160 | 220 | 250 | 100 | 200 | 300 | 590 | 500 | 275 | 45 | |
| RVS-DN 390 | 110 | 200 | 250 | 315 | 125 | 250 | 350 | 590 | 500 | 275 | 45 | |
| RVS-DN 460 | 132 | 250 | 315 | 450 | 150 | 300 | 400 | 623 | 660 | 290 | 65 | |
| RVS-DN 580 | 160 | 315 | 400 | 500 | 200 | 400 | 500 | 623 | 660 | 290 | 65 | |
| RVS-DN 820 | 250 | 450 | 600 | 750 | 300 | 600 | 700 | 623 | 660 | 290 | 65 | |
| RVS-DN 950 | 295 | 500 | 670 | 925 | 400 | 815 | 1030 | D | 623 | 660 | 290 | 83.5 |
| RVS-DN 1100 | 355 | 630 | 800 | 1000 | 400 | 800 | 1000 | 723 | 1100 | 370 | 170 | |
| RVS-DN 1400 | 400 | 800 | 900 | 1300 | 500 | 1000 | 1250 | 723 | 1100 | 370 | 170 | |
| RVS-DN 1800 | 560 | 950 | 1250 | 1500 | 600 | 1250 | 1500 | E | 723 | 1100 | 370 | 170 |
| RVS-DN 2150 | NA | 1250 | 1500 | 2000 | 700 | 1500 | 2000 | F | 750 | 1300 | 392 | 235 |
| RVS-DN 2400 | NA | 1400 | 1750 | 2250 | 800 | 1750 | 2250 | 900 | 1300 | 360 | 350 | |
| RVS-DN 2700 | NA | 1550 | 2000 | 2500 | 900 | 2000 | 2500 | G | 900 | 1300 | 360 | 350 |

* Type test (DNV is type approved as of April 2006)
Notes:
- RVS-DN 8 through RVS-DN 820 are UL & cUL and SCCR Approved (does not apply to RVS-DN-AG, SCCR applies to slim version )
- RVS-DN 1100 and above are designed to meet UL & cUL requirements
- Contact us for RVS-DN 210, 310, 390, 460, 580, 820 & 950 Slim version (Narrow)
- Select the starter according to motor's Full Load Ampere (FLA) - as indicated on its nameplate (even if the motor is not fully loaded)
- The selection table above, concerns standard, 1500 R.P.M. 50Hz, three-phase asynchronous motors. These values are given for guidance and may vary according to individual motor manufacturers (as well as number of poles)
- It is the user's responsibility to verify that motor's FLA does not exceed Starter's FLC