Home > Low Voltage Soft Starters > RVS-DN 1000-1200V

Digital Soft-Starter 1000V and 1200V

RVS-DN - Robust, Full Featured, Motor Protection Enchanced, microprocessor-Based, for motors 105-820A, 150-900KW.

Which soft starter is considered as the most reliable soft starter in todays' Industrial and Marine markets ?

To see examples of these soft starters in demanding conditions check out our Mining, Industial, Naval, Marine, Oil and Gas examples of Solcon soft starters in a variety of applications

Advantages at a Glance:

  • Eliminates high inrush current and damaging mechanical shock
  • Third generation microprocessor circuitry
  • Heavy duty design: 50°C ambient temperature
  • Soft, smooth, stepless acceleration & deceleration
  • Reduced inrush current & mechanical shock
  • Power factor capacitors can be connected directly to the upstream contactor
  • Unique starting & stopping characteristics
  • Sophisticated motor protection package
  • User friendly, easy installation and operation
  • RS485 Communication with MODBUS, PROFIBUS or MODBUS/TCP protocols (others available on request)
  • Wide 45-65Hz Auto-tracking frequency range combining special software with unique hardware arrangement allowing starting and stopping while the frequency variates (designed for Marine, Offshore and Generators operating under continuous frequency variation
  • Unique features such as: Pump Control Program, Dual Adjustment, Slow Speed with Electronic Reversing, Energy Save, etc.
  • Torque and current starting & stopping characteristics

Sophisticated Motor Protection – RVS-DN

  • Long start time (Stall protection)
  • Electronic shear-pin (Jam) with adjustable curves and delay
  • Electronic overload with selectable curves
  • Under current with programmable auto reset
  • Phase loss
  • Phase sequence and Under/Over frequency
  • Under/Over voltage with programmable auto reset
  • Load loss (broken drive belt)
  • External fault
  • Shorted SCR
  • Starter over temperature protection
  • Motor insulation test (option)
  • Motor thermistor (option)
  • When using "Preparation for Bypass" all protective functions remain active

RVS-DN Control

  • All inputs & outputs are isolated.
  • Three C/O output relays.
  • Thermistor input.
  • Analogue output.
  • Communication RS 485 with MODBUS RTU or MODBUS Plus protocols.
  • User friendly keypad interface allowing precise settings.
  • Bright LEDs for immediate visual interface.
  • Interactive and informative 4 language LCD for easy trouble shooting.
  • Statistical data.
  • Motor insulation protection.
  • Hardware and software integration to allow starting from diesel-generator

RVS-DN Construction

  • Heavy duty fully rated design (ambient 50oC).
  • Compact, light weight.
  • Cost efficient plug-in control module, identical for sizes B-D.
  • Preparation for bypass contactor (option), maintaining protection even after bypass closes.

RVS-DN 1000V and 1200V Typical Applications

  • Pumps (Water utilities, Industry)
  • Compressors
  • Conveyors & monorails
  • Mixers & Agitators
  • Fans & Centrifuges
  • Hydraulic pumps
  • Starting from weak Mains supply

RVS-DN 1000V and 1200V Soft Starter

Starter Type Starter Motor Available Dimensions (mm) & Weight
KW HP
1000V 1200V 1000V 1200V 1000V 1200V W H D Kg
RVS-DN 105 - 325 400 300 40
RVS-DN 170 592 500 345 45
RVS-DN 210 592 500 345 45
RVS-DN 310 592 500 345 45
RVS-DN 390 592 500 345 45
RVS-DN 460 592 530 345 50
RVS-DN 580 625 688 345 55
RVS-DN 820 625 688 345 60
Notes:
  • RVS-DN 170A-460A at 1000 and 1200V  are designed to meet UL & cUL requirements

  • Select the starter according to motor's Full Load Ampere (FLA) - as indicated on its nameplate (even if the motor is not fully loaded)

  • The selection table above, concerns standard, 1500 R.P.M. 50Hz, three-phase asynchronous motors. These values are given for guidance and may vary according to individual motor manufacturers (as well as number of poles)

  • It is the user’s responsibility to verify that motor’s FLA does not exceed Starter’s FLA